Development of a Concentration Cell Potentiometric Method for Fe2+ and Fe3+ Speciation

Izzati Izzati, Suheryanto Suheryanto, Poedji Loekitowati Hariani

Abstract


The speciation of Fe2+ and Fe3+ iron ions using the concentration cell potentiometric method has been developed. The determination and speciation of metals that have been used include potentiometry using comparison electrodes, selective ion electrodes, and voltammetry. The concentration cell potentiometric method has the advantages of simple equipment, the use of common metal electrodes, high selectivity, and relatively low detection limits. The method validation results for Fe2+ and Fe3+ ion speciation were LOD: Fe2+ 0.22 mg/L Fe3+ 0.29, LOQ: Fe2+ 0,92 mg/L ; Fe3+ 0,01 mg/L, precision (1.17%; 1.2%) and accuracy (95.57%; 93.15%) based on CV Horwtz.  This method has been well applied for Fe2+ and Fe3+ speciation in natural water samples. The concentrations of Fe2+ and Fe3+ species in Sekanak river water were (1.88 mg/L; 2.07 mg/L). Concentration of Fe2+ and Fe3+ species in well water samples (0.5 mg/L; 1.32 mg/L).

Full Text:

Full Text PDF

References


Novitasari, Eka, dkk. “Sensor Timbal berbasis Potensiometri untuk Mendeteksi Kadar Timbal dalam Darah.” Jurnal Penelitian Saintek, 2016, Vol. 21, No. 1.

Suyanta. 2013. Potensiometri. Yogyakarta: UNY Press.

Aviantara, D.B. “Chemical Speciation Approach in The Risk Evaluation of Environmental Disaster Contaminants Exposure.” Jurnal Sains dan Teknologi Mitigasi Bencana. 2022, Vol. 16, No.2, pp 90-97.

Frag, E.Y.Z., Ali, T.A., Mohamed, G.G and Awad, Y.H.H. “Construction of Different Types of Ion-Selective Electrodes, Characteristic Performances and Validation for Direct Potensiometric Determination of Orphenadrine Citrate.” International Journal of Electrochemical Science. 2012, pp. 4443 – 4446.

Ismail, R., Hai Y.L., Nor, A.M., Fatimah, A.B. “Linearity study on detection and quantification limits for the determination f avermectins using linear regression.” Journal of foods and drug analysis. 2014, pp. 407-412.

Sumarno, D., dan Kusumaningtyas, D.I. “Penentuan Limit Deteksi dan Limit Kuantitasi untuk analisis logam Timbal (Pb) dalam air tawar menggunakan alat spektrofotmeter serapan atom.” Buletin Teknik Litkayasa. 2018, Vol. 16, No. 1, pp. 7-11.

Eurachem Guide: The Fitness for Purpose of Analytical Methods – A Laboratory Guide to Method Validation and Related Topics, Eurachem Guide. 2014, pp. 35 - 36

Peraturan Pemerintah Republik Indonesia Nomor 22 Tahun 2021 tentang Penyelenggaraan Perlindungan dan Pengelolaan Lingkungan Hidup Baku Mutu Air Nasional.

Ulfiati, R., Purnami, T., dan Karina, R.M. “Faktor yang mempengaruhi presisi dan akurasi data hasil uji dalam menentukan kompetensi laboratorium.” 2017, Vol. 51, No. 1, pp. 6-7.

Riyanto. Validasi & Verifikasi Metode Uji. Yogyakarta: Deepublish, 2014, pp. 23-24.

Qadriani, L., Seppewali, A., Aina, A. “Decision tree dan adaboost pada klasifikasi penerima program bantuan social” 2021, Vol. 2, No. 7, pp. 1959 – 1966.

Wisudyaningsih, B. “Studi Performulasi: Validasi metode spektrometri ofiosaksin dalam larutan dapar fosfat.” Stamatognatic (J.K.G Unej), 2012, Vol. 9, No. 2, pp. 77-81.

Shabir, G. A., John, L, W., Arain, S,A., and Bradshaw, T, K., 2007. "Evaluation and application of best practice in analytical method validation." Journal of Liquid Chromatography and Related Technologies, 2007, Vol. 30, No. 3, pp. 311–333.

Zoski, C.G. 2007. Handbook of Electrochemistry. New Mexico: New Mexico State University.




DOI: http://dx.doi.org/10.24845/ijfac.v8.i3.115

Refbacks

  • There are currently no refbacks.


 

Editorial Office:

Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Sriwijaya
Jl. Palembang-Prabumulih Km.35 Indralaya Ogan Ilir Sumatera Selatan 30662

 

 

Creative Commons License
IJFAC by Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Sriwijaya is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License