Preconcentration of Cr(III) Using Dowex 50WX2-200 Resin and Its Application to River Water

Siti Nuraini, Suheryanto Suheryanto, Poedji Loekitowati Hariani

Abstract


Cr(III) is one of the most stable chromium species in nature, Cr(III) species are not carcinogenic to humans, but if the levels in the body exceed 0.2 mg / day it is very dangerous for the body especially in the respiratory tract. The presence of chromium in the aquatic environment is so low that it is very difficult to detect it using instruments with various limitations to detect it, therefore preconcentration techniques are carried out to overcome the issue. In this study the water sample was adjusted pH using HNO3 0.1 M or NaOH 0.1 M, after which it was passed in the dowex column 50WX2-200. Furthermore, an elution process was carried out using the 1 M HNO3 eluent, the eluat was measured for absorbance with flame AAS. The results of Cr(III) preconcentration optimization are: resin weight 0.5 g, HNO3 eluent concentration 1 M, solution pH 3 and sample volume 50 – 100 mL. The Cr(III) preconcentration technique using Dowex 50WX2-200 resin has been applied to river water samples with a detectable concentration of 0.0075 mg/L.

Full Text:

Full Text PDF

References


P. József, N. Dávid, K. Sándor, and B. Áron, “A comparison study of analytical performance of chromium speciation methods,” Microchem. J., vol. 149, p. 103958, Sep. 2019, doi: 10.1016/j.microc.2019.05.058.

A. Ghiasi and A. Malekpour, “Octyl coated cobalt-ferrite/silica core-shell nanoparticles for ultrasonic assisted-magnetic solid-phase extraction and speciation of trace amount of chromium in water samples,” Microchem. J., vol. 154, p. 104530, May 2020, doi: 10.1016/j.microc.2019.104530.

M. B. Arain, I. Ali, E. Yilmaz, and M. Soylak, “Nanomaterial’s based chromium speciation in environmental samples: A review,” TrAC Trends Anal. Chem., vol. 103, pp. 44–55, Jun. 2018, doi: 10.1016/j.trac.2018.03.014.

N. Ozkantar, M. Soylak, and M. Tuzena, “Ultrasonic-assisted Supramolecular Solvent Liquid-liquid Microextraction for Inorganic Chromium Speciation in Water Samples and Determination by UV-Vis Spectrophotometry,” At. Spectrosc., vol. 41, no. 1, pp. 43–50, Feb. 2020, doi: 10.46770/AS.2020.01.006.

N. Altunay and R. Gürkan, “Separation/preconcentration of ultra-trace levels of inorganic Sb and Se from different sample matrices by charge transfer sensitized ion-pairing using ultrasonic-assisted cloud point extraction prior to their speciation and determination by hydride generation AAS,” Talanta, no. 159, pp. 344–355, Oct. 2016, doi: 10.1016/j.talanta.2016.06.054.

S. Nuraini, R. Rosmania, and H. Hartawan, “Prekonsentrasi Cr (VI) Dalam Sampel Air Menggunakan Resin Dowex 50WX2-200,” J. Penelit. Sains, vol. 25, no. 1, p. 50, Mar. 2023, doi: 10.56064/jps.v25i1.754.

S. N. Nuraini and H. Yanti, “Pengaruh Berat Resin dan konsentrasi Eluen Terhadap Prekonsentrasi Logam Pb Menggunakan Resin DOWEX 50WX2-200 Dengan Metode SSA di Laboratorium Pengujian Terpadu FMIPA Universitas Sriwijaya,” J. Penelit. Sains, vol. 23, no. 2, p. 96, Jul. 2021, doi: 10.56064/jps.v23i2.631.

Y. Yuniar and L. Suwartini, “PRE KONSENTRASI LOGAM Cd DALAM AIR MENGGUNAKAN RESIN DOWEX 50WX2 UNTUK PENGUJIAN SECARA SSA- NYALA: PENGARUH BERAT RESIN DAN KONSENTRASI ELUEN”.

K. Saygi, M. Tuzen, M. Soylak, and L. Elci, “Chromium speciation by solid phase extraction on Dowex M 4195 chelating resin and determination by atomic absorption spectrometry,” J. Hazard. Mater., vol. 153, no. 3, pp. 1009–1014, May 2008, doi: 10.1016/j.jhazmat.2007.09.051.

R. Saxena, S. Tiwari, and N. Sharma, “Flow-injection solid phase extraction using Dowex Optipore L493 loaded with dithizone for preconcentration of chromium species from industrial waters and determination by FAAS,” RSC Adv., vol. 5, no. 85, pp. 69196–69204, 2015, doi: 10.1039/C5RA11707K.

O. T. Yayintas, S. Yılmaz, M. Turkoglu, and Y. Dilgin, “Determination of heavy metal pollution with environmental physicochemical parameters in waste water of Kocabas Stream (Biga, Canakkale, Turkey) by ICP-AES,” Environ. Monit. Assess., vol. 127, no. 1–3, pp. 389–397, Feb. 2007, doi: 10.1007/s10661-006-9288-4.

W. Sapyen, S. Toonchue, N. Praphairaksit, and A. Imyim, “Selective colorimetric detection of Cr(VI) using starch-stabilized silver nanoparticles and application for chromium speciation,” Spectrochim. Acta. A. Mol. Biomol. Spectrosc., vol. 274, p. 121094, Jun. 2022, doi: 10.1016/j.saa.2022.121094.

J. Yan, C. Zhang, C. Wang, D. Lu, and S. Chen, “A novel separation and preconcentration methodology based on direct immersion dual-drop microextraction for speciation of inorganic chromium in environmental water samples,” Talanta, vol. 255, p. 123902, Apr. 2023, doi: 10.1016/j.talanta.2022.123902.




DOI: http://dx.doi.org/10.24845/ijfac.v8.i2.105

Refbacks

  • There are currently no refbacks.


 

Editorial Office:

Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Sriwijaya
Jl. Palembang-Prabumulih Km.35 Indralaya Ogan Ilir Sumatera Selatan 30662

 

 

Creative Commons License
IJFAC by Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Sriwijaya is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License